\r\n \r\n
中国专业光学镜片模具及光学组件及光学成型及光学镀膜供应商
先进光学能力
English中文(简体)FrançaisРусскийEspañol
Haze vs. Transmittance in Polymer Optics: Choosing the Right Measurement
» 新闻 & 博客 » Haze vs. Transmittance in Polymer Optics: Choosing the Right Measurement

Haze vs. Transmittance in Polymer Optics: Choosing the Right Measurement

11 月 12, 2026

A transparent part can transmit plenty of light and still blur the scene behind it. Another can preserve sharp detail while reducing brightness. These observations point to different optical behaviors, so a purchase requirement that asks only for “high transparency” leaves room for incompatible interpretations.

Haze, transmittance and clarity help describe those behaviors. The right measurement depends on whether the component is a window, an imaging lens, a light guide or an intentional diffuser, and on whether the test specimen represents the delivered part.

Separate the amount of light from its distribution

Total transmittance describes how much incident light passes through the specimen under the measurement conditions. Haze describes the fraction of transmitted light scattered through wider angles. For the D1003 approach discussed below, the angular boundary is 2.5 degrees from the incident beam. Clarity addresses the effect of narrow-angle scattering on the visibility of fine detail.

BYK-Gardner's transparency measurement white paper explains these distinctions and the different visual effects of wide- and narrow-angle scattering. Consequently, a high total-transmittance result alone does not establish low haze or good image detail. These quantities should not be combined into a single informal “clarity percentage.”

For a sensor application, also identify the wavelength range. A visible luminous-transmittance result does not establish transmission throughout a near-infrared operating band. Request the spectral information needed by the actual source and detector when a visible-light metric is insufficient.

Check whether the specimen fits the method

ASTM D1003 covers specific transmitting and wide-angle-scattering properties of planar sections of essentially transparent plastics. It provides a hazemeter procedure and a spectrophotometer procedure. The public scope matters here: a strongly curved lens is not automatically equivalent to a flat specimen.

A powered lens deliberately changes ray direction. Before placing it in a haze instrument, ask the laboratory how its curvature, aperture and position affect the measurement and whether the method is applicable. Otherwise, light redirected by the lens can be confused with the scattering behavior that the test is intended to assess.

If a flat molded witness plaque is used, label the result as a plaque result. It may help evaluate a material or controlled process, but it does not by itself demonstrate the finished lens's imaging performance. Do not report it as a direct measurement of every delivered lens.

Define the comparison specimen

Specify the material grade, thickness, surface condition and manufacturing route of the test sample. For coated parts, state whether measurements apply before coating, after coating or to both stages. Retain the identity of each specimen so a later result can be connected to its history.

When comparing candidate materials, use an agreed specimen preparation and geometry. A thicker sample or a different surface finish can make a comparison misleading even when both reports are technically correct. Supplier datasheet values are useful for screening, but check their specimen and method information before treating small differences as a purchasing decision.

For a molded optical part, explain what the specimen is intended to represent. A material-screening coupon, a process-control sample and a finished-product acceptance sample answer different questions.

Read the method details before comparing values

Record the standard edition and procedure, instrument configuration, illumination conditions, specimen position and tested area. ASTM's published discussion notes that Procedure A and Procedure B can produce different haze results. Values obtained through different procedures should not be assumed interchangeable simply because both reports cite D1003.

Ask for repeat measurements appropriate to the decision, particularly when differences are small. Check that the instrument and sample presentation can resolve the proposed acceptance limit. More digits on a report do not establish that a narrow difference is meaningful.

Include these choices in the optical quality requirements. They belong beside the acceptance value, not in an undocumented laboratory habit.

Pair the number with the component's job

For a protective window in front of a camera, haze may be relevant alongside an imaging test in the intended arrangement. For a molded lens, evaluate the specified optical function rather than substituting a flat-plaque transparency result. For an intentional diffuser, useful scattering can be part of the design, so minimizing haze is not automatically the correct objective. Confirm that the chosen method covers the scattering range; D1003 directs materials above 30% haze to Practice E2387.

When an unexplained change appears, preserve the sample and investigate its location and history. A single haze result does not identify whether the cause is a surface change, an internal feature or contamination. Avoid prescribing a process adjustment from the number alone.

A well-written requirement names the property, applicable method, representative specimen and functional reason for the limit. That gives the buyer and manufacturer a shared basis for deciding whether a transparent component is suitable for its intended use.

新闻 & 博客

也许你也喜欢

  • 服务 & 产能

  • 资源

    • 新闻
    • 博客
    • 案例研究
    • 下载